The Swimmming pool pump is the heart of your pool circulation system. And just like your precious heart, when the pool pump stops working, nothing works.
How to maintain a healthy pool pump, to avoid any unexpected pump problems, which can cause water problems, fast. Problem: Water expands 9% when it turns into ice, and this can rupture a pool pump volute or strainer housing, causing cracks that require part replacement. Solution: Keep the pump running during cold temperatures. As long as water is moving through the pipes, nothing will freeze. If it is not possible to run the pump, remove both pump drain plugs (and filter plugs, heater plugs, chlorinator, etc.). With freeze protection for pool equipment, a pool controller or a digital timeclock can use a freeze sensor, which will turn on the pump automatically. FLOODED POOL PUMP Problem: When motors are submerged under water, the drowning is usually fatal. Occasionally a partially submerged motor will survive, if taken apart and dried internally, unless it was running at the time of the flooding! Many pumps start out their lives well above the ground, but over years, sediment and debris can raise the ground until there is very little clearance. Solution: Raise the pump, or lower the ground! Be sure that the area around your pool equipment drains rapidly during heavy rains. If flood waters threaten your pool pump, sand bag the pad, or remove the pump to higher ground until waters recede. If water no longer runs away from the equipment quickly, dig out any in-fill or soils that have washed up against the pad, grading slopes and swales to carry water away. Add gravel around the pump and filter area to reduce moisture and slow weed growth. DRY POOL PUMP Problem: Pumps that ‘run dry’ (without incoming water) for long periods of time can blow out the shaft seal and begin leaking. In some cases it will melt pump baskets and even deform the pump volute. Resulting high temps also will shrink the threads on PVC fittings threaded in/out of the pump, causing air leaks on the inlet side, and water leaks around the outlet pipe fitting. Solution: Maintaining a proper water level in the pool is the first advice. Secondly, hunt down and fix any air leaks on the incoming pipes or suction cleaner hoses, which can cause the pump to lose prime. Finally, be sure that the pump lid is lubed and tight, and drain plugs are Teflon taped and tight. The other common air leak is around melted and shrunk PVC fittings threaded into the pump, as mentioned above. Replace the shrunken fitting, or make a patch with Pool Putty. WRONG SIZE PUMPProblem: Pumps that are too big for the pipe size or number of incoming pipes will cavitate under excessive vacuum pressure, essentially starved for water. And pool pumps that are too small for the system will struggle against a heavy resistance pressure. In both cases, the pump and motor is overworked; a leading cause of heart (pump) failure. Solution: Select new pool pumps based on a careful consultation of the Pump Flow Curve, with a good estimate of your system resistance, and the knowledge of your Filter Design Flow Rate. Replacing with the exact duplicate pump is a good bet,variable speed pump can be optimized to match system resistance. When in doubt, contact our call center to speak with a pool tech, or leave me a comment below. We need to know all about your pool and every piece of equipment, and how far the equipment is from the pool, pipe size and type of pipe used, among other details. Get more info Swimming Pool Pump Dubai. WRONG PUMP WIRING Problem: Incorrect voltage, wire size or wiring. High or low voltage over time can stress the motor, or just flat burn it out, causing a short across the windings or blowing out the capacitor repeatedly. Pool motors are available in 120V and 240V (only), and also 120V/240V, known as reversible motors, able to accept either voltage. Connecting 120V into a motor that is expecting 240V just won’t start the motor, but putting 240V into a motor wired for 120V and you can expect sparks and smoke and a dead motor if not shut off quickly! Mis-wired motors, or using incorrect wire size could also cause motor problems. Solution: Line voltage should be stable and within 10% of 115V or 230V, whichever is used. When installing a new motor, double check that line voltage matches motor voltage. Read the wiring diagram closely on the motor label to be sure that your power leads and ground wire are correctly attached to the terminal board. Although modern motors are fairly straight-forward with the power connection, it is possible to mis-wire a motor. And, if replacing old wires, be sure to use the correct wire size, usually 12/3, or 12 AWG size, three wires, usually white,
0 Comments
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |
Contact UsAl Qusais Industrial Area 1, Dubai, UAE
P.O.Box 12940 Tel: +971 4 252 2966 Fax: +971 4 297 7388 Email:sales@dxbsolutions.ae |
Products |
|